Field Application of Portable Ultrasonic Flow Meter for Well Flow Depletion Measurement

Document Type : Original Research

Authors
Department of Water Engineering, Imam Khomeini International University, Postal-Code: 34149-16818, Qazvin, Iran.
Abstract
Field observations of flow measurement difficulties using portable ultrasonic flow meters are reported in this work. Accordingly, pipe wall thickness and sensors’ spacing were identified as two important sources of the in-situ flow measurement inaccuracies. Experimental tests were accomplished to evaluate the effect of input parameters on the performance of the portable ultrasonic flow meters. Iron and Unplasticized Poly Vinyl Chloride (UPVC) pipes of the outer diameters of 3, 4, and 8 inches were tested. For all tested cases, the pipe wall thickness increase would affect the ultrasonic performance more than the cases with the wall thickness decrease. A mixed effect of the sensors’ spacing was observed for the changes in pipe material/dimensions. Finally, a correction equation was proposed to improve the flow measurements.

Keywords

Subjects


Carlander, C., and J. Delsing. 2000. “Installation effects on an ultrasonic flow meter with implications for self diagnostics.” Flow Meas. Instrum., 11 (2): 109–122. https://doi.org/10.1016/S0955-5986(00)00005-4.
Dutta, P., and A. Kumar. 2017. “Intelligent calibration technique using optimized fuzzy logic controller for ultrasonic flow sensor.” Math. Model. Eng. Probl., 4 (2): 91–94. https://doi.org/10.18280/mmep.040205.
Inoue, Y., H. Kikura, H. Murakawa, M. Aritomi, and M. Mori. 2008. “A study of ultrasonic propagation for ultrasonic flow rate measurement.” Flow Meas. Instrum., 19 (3–4): 223–232. https://doi.org/10.1016/j.flowmeasinst.2007.06.013.
Meena, A., H. S. Mali, A. Patnaik, and S. R. Kumar. 2018. Investigation of wear characteristics of dental composites filled with nanohydroxyapatite and mineral trioxide aggregate. Fundam. Biomater. Polym. Elsevier Ltd.
Stoker, D. M., S. L. Barfuss, and M. C. Johnson. 2012. “Ultrasonic Flow Measurement for Pipe Installations with Nonideal Conditions.” J. Irrig. Drain. Eng., 138 (11): 993–998. https://doi.org/10.1061/(asce)ir.1943-4774.0000486.
Su, M., X. Jiao, J. Li, S. Wu, and T. Wu. 2021. “Accuracy and reliability analysis of pipe irrigation metering device for sandy water source.” Water (Switzerland), 13 (7): 1–14. https://doi.org/10.3390/w13070947.
Svensson, B., and J. Delsing. 1998. “Application of ultrasonic clamp-on flow meters for in situ tests of billing meters in district heating systems.” Flow Meas. Instrum., 9 (1): 33–41. https://doi.org/10.1016/S0955-5986(98)00007-7.
Tawackolian, K., O. Büker, J. Hogendoorn, and T. Lederer. 2013. “Calibration of an ultrasonic flow meter for hot water.” Flow Meas. Instrum., 30: 166–173. https://doi.org/10.1016/j.flowmeasinst.2012.05.003.
Wang, C., T. Meng, H. ming Hu, and L. Zhang. 2012. “Accuracy of the ultrasonic flow meter used in the hydroturbine intake penstock of the Three Gorges Power Station.” Flow Meas. Instrum., 25: 32–39. Elsevier Ltd. https://doi.org/10.1016/j.flowmeasinst.2011.12.003.