Structural stability analysis of naturally ventilated polyhouses under different conditions

Document Type : Original Research

Authors
1 Department of Soil and Water Engineering, Punjab Agricultural University, Ludhiana, Punjab, India 141004.
2 Department of Civil Engineering, Punjab Agricultural University, Ludhiana, Punjab, India 141004.
3 Department of Soil and Water Engineering, Punjab Agricultural University, Ludhiana, Punjab, India 141004
Abstract
This research work on structural stability analysis of naturally ventilated polyhouses was carried out at the Department of Soil and Water Engineering, Punjab Agricultural University, Ludhiana. There were 12 treatments which were combination of four different sizes of polyhouses i.e. 560 (T1-T3); 1,008 (T4-T6); 2,080 (T7-T9); 4,000 m2 (T10-T12), with three design wind speeds of 100, 150, and 200 km h-1, respectively. Stability analysis of truss members, columns, and foundation was carried out by considering dead loads, live loads and wind loads. Support reactions were computed on truss and column joints. Member forces were computed by using force method. For every 17 set of truss members, four members [two in compression (small arc) and two in tension (truss bracings)] failed in treatments with 150 and 200 km h-1 wind speed, while in treatments with 100 km h-1 wind speed, two members [in compression, (small arc)] failed. Minimum structural GI pipe material requirement for structurally stable polyhouses was under treatment T1 (2,407 kg) and the maximum was under treatment T12 (19,550 kg).

Keywords

Subjects


Anonymous (2019) Technical standards for naturally ventilated, fan and pad green house and shade net house. www.nhb.gov.in (accessed 16 April, 2019)
Elsner B V, Briassoulis D, Waaijenberg D, Mistriotis A, Zabeltitz C V, Gratraud J and Suay C R (2000) Review of structural and functional characteristics of greenhouses in European :union: countries: Part I, design requirements. J Agric Engg Res75: 1-16.
IS:14462 (1997) Recommendations for layout, design and construction of greenhouse structures. Pp 1- 13. Bureau of Indian standard, New Delhi.
IS:800 (2007) General construction in steel code of practice. Pp 1 – 150. Bureau of Indian standard, New Delhi.
IS:875 PART 1 (1987) Code of practice for design loads (other than earthquake) for buildings and structures. Pp 1 – 43. Bureau of Indian standard, New Delhi.
IS:875 PART 2 (1987) Code of practice for design loads (other than earthquake) for buildings and structures. Pp 1 – 23. Bureau of Indian standard, New Delhi.
IS:875 PART 3 (1987) Code of practice for design loads (other than earthquake) for buildings and structures. 1 – 67. Bureau of Indian standard, New Delhi.
IS:875 PART 3 (2015) Code of practice for design loads (other than earthquake) for buildings and structures. Pp 1 – 63. Bureau of Indian standard, New Delhi.
IS:875 PART 4 (1987) Code of practice for design loads (other than earthquake) for buildings and structures. Pp 1 – 11. Bureau of Indian standard, New Delhi.
IS:875 PART 5 (1987) Code of practice for design loads (other than earthquake) for buildings and structures. Pp 1 – 24. Bureau of Indian standard, New Delhi.
Jensen M H and Malter A J (1994) Protected agriculture a global review. World Bank technical paper, number 253, Washington, D.C.
Kyrikou I, Briassoulis D, Hiskakis M and Babou E (2011) Analysis of photo-chemical degradation behavior of polyethylene mulching film with pro-oxidants. Polymer Degradation Stab96: 2237-52.
Nayak A K and Rao K R (2014) Estimation of wind load on a greenhouse and evaluation of its structural stability. Int J Agric Engg7:461-66.
Nayak A K, Rao K R, Saxena C K and Kumar M (2018) Estimation of various loads of a naturally ventilated saw tooth type greenhouse. Andhra Agric J 65:538-43.
Wittwer S H and Castilla N (1995) Protected cultivation of horticultural crops worldwide. Hort Tech5: 6-23.