<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Tarbiat Modares University</PublisherName>
				<JournalTitle>Journal of Agricultural Science and Technology</JournalTitle>
				<Issn>1680-7073</Issn>
				<Volume>17</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>07</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Modeling the Simultaneous Effects of Microwave and Ultrasound Treatments on Sour Cherry Juice Using Response Surface Methodology</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>837</FirstPage>
			<LastPage>846</LastPage>
			<ELocationID EIdType="pii">15742</ELocationID>
			
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>B.</FirstName>
					<LastName>Hosseinzadeh Samani</LastName>
<Affiliation>Biosystems Engineering Department, Tarbiat Modares University, P. O. Box: 14115-139, Tehran, Islamic Republic of Iran.</Affiliation>

</Author>
<Author>
					<FirstName>M. H.</FirstName>
					<LastName>Khoshtaghaza</LastName>
<Affiliation>Biosystems Engineering Department, Tarbiat Modares University, P. O. Box: 14115-139, Tehran, Islamic Republic of Iran.</Affiliation>

</Author>
<Author>
					<FirstName>S.</FirstName>
					<LastName>Minaee</LastName>
<Affiliation>Biosystems Engineering Department, Tarbiat Modares University, P. O. Box: 14115-139, Tehran, Islamic Republic of Iran.</Affiliation>

</Author>
<Author>
					<FirstName>S.</FirstName>
					<LastName>Abbasi</LastName>
<Affiliation>Department of Food Science and Technology, Tarbiat Modares University, P. O. Box: 14115-139, Tehran, Islamic Republic of Iran.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
		<Abstract>This study aimed to examine the effectiveness of combined microwave-ultrasonic pasteurization system on &lt;em&gt;Escherichia coli &lt;/em&gt;and vitamin C content in sour cherry juice (SCJ). Based on the findings, microwave output power, ultrasound power, and ultrasonic exposure time as well as the microwave-induced temperature were the most effective factors in reducing &lt;em&gt;E. coli &lt;/em&gt;and vitamin C content. In addition, the microwave-induced temperature and ultrasonic exposure time, as independent variables, were both effective on &lt;em&gt;E. coli &lt;/em&gt;removal. At higher temperatures, the effectiveness of ultrasonic waves as well as cavitation intensity declined. However, their combined effect (ultrasound and temperature) was more significant than their individual effect. It was also found that any increase in ultrasound power, ultrasonic exposure time, and microwave output power led to a significant reduction in vitamin C content, while the ultrasound power was the most effective. On the basis of &lt;em&gt;RSM&lt;/em&gt; modeling, the optimum processing condition was: 352.21W microwave output power, 49.94˚C temperature, 475.13W ultrasound power and 6 minutes of exposure time. On the basis of response surface methodology (RSM) modelling, the maximum vitamin C content was 142.5 mg per 100 mL with no remaining &lt;em&gt;E. coli&lt;/em&gt;.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">cavitation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Microwave output power</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Pasteurization</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Ultrasound power</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jast.modares.ac.ir/article_15742_1b12189170921fa4ac5414db98f542de.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
